02590 93 895-26 Contact us
  • My Account
  • Checkout
  • About Hagelschuer
0 You have no items in your shopping cart.

Heat exchanger station

Steam-water heat exchanger

5 Item(s)

Set Ascending Direction

Heat exchanger station 1000 KW for 2.5-13.0 bar(g) steam pressure

Heat exchanger station 1000 KW heat output up to max. 100 °C flow temperature for 2.5-13.0 bar(g) steam pressure with condensate accumulation control consisting of:

- Standing tube bundle heat exchanger with CE marking according to DGRL and AD 2000 data sheets for condensate-side control with condensate cooling, tube heating bundle made from straight smooth precision tubes incl. insulation painted on the outside

Steam-side fittings comprising:
- Shut-off as motorised or pneumatic shut-off valve with safety function
- Manual shut-off valve
- Dirt trap
- Vacuum breaker
- Venting system

Condensate-side fittings comprising:
- Manual shut-off valve
- Dirt trap
- Motorised or pneumatic control valve for condensate build-up
- Steam trap
- Inspection glass for flow control

Secondary-side fittings comprising:
- PT 100 temperature sensor for temperature measurement
- Safety thermostat
- Where applicable, pressure limiter min. or pressure limiter max.
- Safety valve to prevent impermissible overpressure on the secondary side

Temperature control comprising:
- Switchgear for operating and monitoring the heat exchanger station, switching the shut-off valve with safety device and controlling the condensate build-up, incl. installation and wiring of the 3-point step controller, where applicable integration of the signals pressure limiter min. or max., setpoint adjustment on the industrial controller

- Compl. pre-assembly of the previously described components on a base frame pre-installed ready for connection and pre-wired
€22,420.53
Learn More

Heat exchanger station 800 KW for 2.5-13.0 bar(g) steam pressure

Heat exchanger station 800 KW heat output up to max. 100 °C flow temperature for 2.5-13.0 bar(g) steam pressure with condensate accumulation control consisting of:

- Standing tube bundle heat exchanger with CE marking according to DGRL and AD 2000 data sheets for condensate-side control with condensate cooling, tube heating bundle made from straight smooth precision tubes incl. insulation painted on the outside

Steam-side fittings comprising:
- Shut-off as motorised or pneumatic shut-off valve with safety function
- Manual shut-off valve
- Dirt trap
- Vacuum breaker
- Venting system

Condensate-side fittings comprising:
- Manual shut-off valve
- Dirt trap
- Motorised or pneumatic control valve for condensate build-up
- Steam trap
- Inspection glass for flow control

Secondary-side fittings comprising:
- PT 100 temperature sensor for temperature measurement
- Safety thermostat
- Where applicable, pressure limiter min. or pressure limiter max.
- Safety valve to prevent impermissible overpressure on the secondary side

Temperature control comprising:
- Switchgear for operating and monitoring the heat exchanger station, switching the shut-off valve with safety device and controlling the condensate build-up, incl. installation and wiring of the 3-point step controller, where applicable integration of the signals pressure limiter min. or max., setpoint adjustment on the industrial controller

- Compl. pre-assembly of the previously described components on a base frame pre-installed ready for connection and pre-wired
€20,679.03
Learn More

Heat exchanger station 600 KW for 2.5-13.0 bar(g) steam pressure

Heat exchanger station 600 KW heat output up to max. 100 °C flow temperature for 2.5-13.0 bar(g) steam pressure with condensate accumulation control consisting of:

- Standing tube bundle heat exchanger with CE marking according to DGRL and AD 2000 data sheets for condensate-side control with condensate cooling, tube heating bundle made from straight smooth precision tubes incl. insulation painted on the outside

Steam-side fittings comprising:
- Shut-off as motorised or pneumatic shut-off valve with safety function
- Manual shut-off valve
- Dirt trap
- Vacuum breaker
- Venting system

Condensate-side fittings comprising:
- Manual shut-off valve
- Dirt trap
- Motorised or pneumatic control valve for condensate build-up
- Steam trap
- Inspection glass for flow control

Secondary-side fittings comprising:
- PT 100 temperature sensor for temperature measurement
- Safety thermostat
- Where applicable, pressure limiter min. or pressure limiter max.
- Safety valve to prevent impermissible overpressure on the secondary side

Temperature control comprising:
- Switchgear for operating and monitoring the heat exchanger station, switching the shut-off valve with safety device and controlling the condensate build-up, incl. installation and wiring of the 3-point step controller, where applicable integration of the signals pressure limiter min. or max., setpoint adjustment on the industrial controller

- Compl. pre-assembly of the previously described components on a base frame pre-installed ready for connection and pre-wired
€18,265.69
Learn More

Heat exchanger station 400 KW for 2.5-13.0 bar(g) steam pressure

Heat exchanger station 400 KW heat output up to max. 100 °C flow temperature for 2.5-13.0 bar(g) steam pressure with condensate accumulation control consisting of:

- Standing tube bundle heat exchanger with CE marking according to DGRL and AD 2000 data sheets for condensate-side control with condensate cooling, tube heating bundle made from straight smooth precision tubes incl. insulation painted on the outside

Steam-side fittings comprising:
- Shut-off as motorised or pneumatic shut-off valve with safety function
- Manual shut-off valve
- Dirt trap
- Vacuum breaker
- Venting system

Condensate-side fittings comprising:
- Manual shut-off valve
- Dirt trap
- Motorised or pneumatic control valve for condensate build-up
- Steam trap
- Inspection glass for flow control

Secondary-side fittings comprising:
- PT 100 temperature sensor for temperature measurement
- Safety thermostat
- Where applicable, pressure limiter min. or pressure limiter max.
- Safety valve to prevent impermissible overpressure on the secondary side

Temperature control comprising:
- Switchgear for operating and monitoring the heat exchanger station, switching the shut-off valve with safety device and controlling the condensate build-up, incl. installation and wiring of the 3-point step controller, where applicable integration of the signals pressure limiter min. or max., setpoint adjustment on the industrial controller

- Compl. pre-assembly of the previously described components on a base frame pre-installed ready for connection and pre-wired
€16,788.93
Learn More

Heat exchanger station 200 KW for 2.5-13.0 bar(g) steam pressure

Heat exchanger station 200 KW heat output up to max. 100 °C flow temperature for 2.5-13.0 bar(g) steam pressure with condensate accumulation control consisting of:

- Standing tube bundle heat exchanger with CE marking according to DGRL and AD 2000 data sheets for condensate-side control with condensate cooling, tube heating bundle made from straight smooth precision tubes incl. insulation painted on the outside

Steam-side fittings comprising:
- Shut-off as motorised or pneumatic shut-off valve with safety function
- Manual shut-off valve
- Dirt trap
- Vacuum breaker
- Venting system

Condensate-side fittings comprising:
- Manual shut-off valve
- Dirt trap
- Motorised or pneumatic control valve for condensate build-up
- Steam trap
- Inspection glass for flow control

Secondary-side fittings comprising:
- PT 100 temperature sensor for temperature measurement
- Safety thermostat
- Where applicable, pressure limiter min. or pressure limiter max.
- Safety valve to prevent impermissible overpressure on the secondary side

Temperature control comprising:
- Switchgear for operating and monitoring the heat exchanger station, switching the shut-off valve with safety device and controlling the condensate build-up, incl. installation and wiring of the 3-point step controller, where applicable integration of the signals pressure limiter min. or max., setpoint adjustment on the industrial controller

- Compl. pre-assembly of the previously described components on a base frame pre-installed ready for connection and pre-wired
€15,573.58
Learn More

5 Item(s)

Set Ascending Direction